Cisco Systems CompactFlash Adapter Installationshandbuch Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
8
Cisco CompactFlash Adapter for Bootflash Upgrade Installation Note
78-17277-04
Installing the SP Bootflash Memory Upgrade Kit
Installing the SP Bootflash Memory Upgrade Kit
The SP memory upgrade procedure is divided into the following tasks:
Verifying the SP ROMMON Version, page 8
Upgrading and Verifying the SP ROMMON Image, page 8
Removing the Supervisor Engine 720, page 10
Installing the CompactFlash Adapter, page 13
Reinstalling the Supervisor Engine 720, page 16
Verifying the SP ROMMON Version
An SP ROMMON upgrade may be required to support the CompactFlash adapter; you must determine
what SP ROMMON release is installed on the Supervisor Engine 720 prior to performing an SP
ROMMON upgrade. The minimum SP ROMMON release required is 8.4(2). To determine the currently
running SP ROMMON release, enter the remote command switch show version | include ROM
command
If your system is running SP ROMMON Release 8.4(2) or a later release, you can continue on to
“Removing the Supervisor Engine 720” section on page 10. If your SP ROMMON release is earlier than
8.4(2), you must upgrade the SP ROMMON image. Go to the “Upgrading and Verifying the SP
ROMMON Image” section on page 8.
Upgrading and Verifying the SP ROMMON Image
In order to utilize the SP CompactFlash adapter, your Supervisor Engine 720 must have SP ROMMON
Release 8.4(2) or a later release installed on it.
Note The upgrade task description is based on the Supervisor Engine 720 installed in a 9-slot chassis currently
running ROMMON from its S (Gold) region; the ROMMON upgrade to support the CompactFlash
adapter will be done in the F1 region.
Seitenansicht 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 39 40

Kommentare zu diesen Handbüchern

Keine Kommentare