Chapter 4 Installation and Maintenance
Removing and Replacing a Power Supply Unit
SCE 2000 4xGBE Installation and Configuration Guide
4-22 OL-7824-02
Note
The power supply is not fully seated until you tighten the installation screw on the faceplate.
This completes the procedures for replacing a power supply in a SCE 2000 platform.
Reconnecting the Power
The following sections describe how to reconnect the AC or DC power:
Reconnecting AC-Input Power Supply Unit (on page 4-22)
Reconnecting DC-Input Power Supply Unit (on page 4-23)
Reconnecting AC-Input Power Supply Unit
The following procedures explain how to reconnect an AC-input power to the SCE 2000
platform.
If you are reconnecting DC-input power, proceed to Reconnecting DC-Input Power Supply Unit
(on page 4-23).
To reconnect the AC-input power to the SCE 2000 platform, complete the following steps:
Step 1 Plug the AC-input power cable into the AC-input power receptacle on the AC-input
power supply
Figure 4-14: Connecting the AC Power