9-6
Cisco WAN Modeling Tools Guide
OL-10426-01, Rev. A0
Chapter 9 Configuration Extraction Tool
Troubleshooting CET
Symptom Connections are missing.
Probable Causes Incomplete data in SV+ database.
Solution CWM 9.2 or higher: View the files that begin with the word extra. These contain
connection segments that are in the data base, but which were not collected because
they were not part of an end-to-end connection.
SV+ 7.0 - SV+ 9.1: View the files maybe.voice.svp, maybe_data.svp,
maybe_frame.svp, and maybe_atm.svp.
If you find the connections, try rerunning svp2cet and cet2nmt.
If this doesn’t succeed, contact WAN Manager support.
Symptom Informix Error 862 (cannot open file for run)
Probable Causes cetlink has not been run.
User is executing CET from a subdirectory
CET installation did not execute properly.
Solution Make sure this directory contains cetbin:
ls-1 cetbin
if cetbin is not there, run cetlink
See if all required subdirectories and programs are in cetbin. If they are not
there, you must reinstall CET.
Symptom Informix Error 529 (Cannot attach to shared memory)
Informix Error 123 (ISAM error: No shared memory)
Probable Causes Informix DB is not on line.
Solution 1 Become the Superuser INFORMIX
2Type cd
3Type tbmonitor, or bin/tbmonitor
4In tbmonitor, select mode. This will confirm that the database is off-line.
5 Select start-up.
The database is brought from off-line to quiescent.
6 Select on-line.
This brings the database on-line
7 Select exit to exit mode.
8 Select exit to exit tb monitor
9 Exit informix